What the IEC 60534 series covers
IEC 60534 is published by the International Electrotechnical Commission under the title Industrial-process control valves. Each part is a separate document with its own edition. The table lists the parts that bid engineers meet most often.
| Part | What it covers in outline |
|---|---|
| Part 1 | Control valve terminology and general considerations |
| Part 2-1 | Flow capacity: sizing equations for fluid flow under installed conditions |
| Part 2-3 | Flow capacity: test procedures |
| Part 2-4 | Inherent flow characteristics and rangeability |
| Part 3-1 | Face-to-face dimensions for flanged, two-way, globe-type control valves |
| Part 4 | Inspection and routine testing, including seat leakage classes |
| Part 5 | Marking |
| Part 6 | Mounting details for attaching positioners to control valves |
| Part 7 | Control valve data sheet |
| Parts 8-3 and 8-4 | Noise prediction: aerodynamic (8-3) and hydrodynamic (8-4) flow |
What to check in a control valve datasheet against the tender
Work tag by tag. Any gap becomes a row in your technical deviation list.
| Item | Check against | Typical deviation source |
|---|---|---|
| Process cases | Tender data sheet | Minimum or maximum case missing; units unclear |
| Sizing result and travel | Specification limits on travel at each case | Rated capacity too close to maximum case |
| Flow characteristic | Data sheet | Linear offered where equal percentage is specified, or the reverse |
| Seat leakage class | Specification and data sheet | Class IV offered where V or VI is required |
| Predicted noise | Project noise limit and prediction method | Prediction above limit; method or basis not stated |
| Body, trim and packing | Piping class, sour-service and emission requirements | Trim or packing outside specified materials or class |
| Face-to-face and ends | Piping class | Different face-to-face standard or flange facing |
| Actuator | Fail action, air supply, stroking time | Fail action or stroke time not met |
| Positioner and accessories | Signal, protocol, solenoids, switches | Different protocol or accessory make |
| Tests and documents | ITP and VDRL | Extra witness tests or calculations not priced |
Where IEC 60534 sits with other requirements
A control valve tender usually adds a pressure-temperature rating standard such as ASME B16.34, sour-service rules such as NACE MR0175 / ISO 15156, fugitive emission testing to ISO 15848-1 and certificates to EN 10204. If the valve is a final element in a safety function, the tender will also cite IEC 61508 and IEC 61511.
Where OdysseyGPT fits
OdysseyGPT reads the whole tender package, lists each requirement with a quote and page, and checks it against your own datasheets and test procedures. It does not run sizing or noise calculations. See OdysseyGPT for manufacturing and instrumentation manufacturers.
Talk through your tender review
See how OdysseyGPT reviews a tender
Tell us how your team reviews tenders today. We can walk through an example together.